8-port managed Ethernet switch with cybersecurity features (with options of 4 802.3bt PoE ports or 4 Giga uplink ports)
The EDS-4008 Series is a range of 8-port managed Fast Ethernet switches with the option for four 1 Gbps uplink ports or two 100M ST/SC fiber-optic ports.
Name | Action |
---|---|
EDS-4008-series |
Ethernet Interface | |
10/100BaseT(X) Ports (RJ45 connector) | EDS-4008-LV/-HV/-T models: 8 |
EDS-4008-2MST-LV/-HV/-T models: 6 | |
EDS-4008-2MSC-LV/-HV/-T models: 6 | |
EDS-4008-2SSC-LV/-HV/-T models: 6 | |
EDS-4008-2GT-2GS-LV/-HV/-T models: 4 | |
Auto negotiation speed | |
Full/Half duplex mode | |
Auto MDI/MDI-X connection | |
PoE Ports (10/100BaseT(X), RJ45 connector) | EDS-4008-4P-2GT-2GS-LVA/-LVB/-T models: 4 |
100BaseFX Ports (multi-mode SC connector) | EDS-4008-2MSC-LV/-HV/-T models: 2 |
100BaseFX Ports (multi-mode ST connector) | EDS-4008-2MST-LV/-HV/-T models: 2 |
100BaseFX Ports (single-mode SC connector) | EDS-4008-SSC-LV/-HV/-T models: 2 |
10/100/1000BaseT(X) Ports (RJ45 connector) | EDS-4008-2GT-2GS-LV/-HV-T models: 2 |
EDS-4008-4P-2GS-2GT-LVA/-LVB/-T models: 2 | |
100/1000BaseSFP Slots | EDS-4008-2GT-2GS-LV/-HV/-T models 2 |
EDS-4008-4P-2GT-2GS-LVA/-LVB/-T models: 2 | |
Standards | IEEE 802.3 for 10BaseT |
IEEE 802.3u for 100BaseT(X) and 100BaseFX | |
IEEE 802.3ab for 1000BaseT(X) | |
IEEE 802.3z for 1000BaseX | |
IEEE 802.3x for flow control | |
IEEE 802.3ad for Port Trunk with LACP | |
IEEE 802.1Q for VLAN Tagging | |
IEEE 802.1D-2004 for Spanning Tree Protocol | |
IEEE 802.1w for Rapid Spanning Tree Protocol | |
IEEE 802.1p for Class of Service | |
IEEE 802.1X for authentication | |
Ethernet Software Features | |
Filter | GMRP, GVRP, GARP, 802.1Q VLAN, IGMP Snooping v1/v2/v3, IGMP Querier |
Management | IPv4/IPv6, Flow control, Back Pressure Flow Control, DHCP Server/Client, ARP, RARP, LLDP, Port Mirror, Linkup Delay, SMTP, SNMP Trap, SNMP Inform, SNMPv1/v2c/v3, RMON, TFTP, SFTP, HTTP, HTTPS, Telnet, Syslog, Private MIB |
MIB | P-BRIDGE MIB, Q-BRIDGE MIB, IEEE8021-SPANNING-TREE-MIB, IEEE8021-PAE-MIB, IEEE8023-LAG-MIB, LLDP-EXT-DOT1-MIB, LLDP-EXT-DOT3-MIB, SNMPv2-MIB, RMON MIB Groups 1, 2, 3, 9 |
Redundancy Protocols | STP, RSTP, Turbo Ring v2, Turbo Chain, Ring Coupling, Dual-Homing, Link Aggregation |
Security | Broadcast storm protection, Rate Limit, Trust access control, Static Port Lock, MAC Sticky, HTTPS/SSL, SSH, RADIUS, TACACS+, Login and Password Policy |
Time Management | SNTP, NTP Server/Client, NTP Authentication |
Protocols | IPv4/IPv6, TCP/IP, UDP, ICMP, ARP, RARP, TFTP, DNS, NTP Client, DHCP Server, DHCP Client, 802.1X, QoS, HTTPS, HTTP, Telnet, SMTP, SNMPv1/v2c/v3, RMON, Syslog |
Switch Properties | |
MAC Table Size | 16 K |
Jumbo Frame Size | 9.216 KB |
Max. No. of VLANs | 256 |
VLAN ID Range | VID 1 to 4094 |
IGMP Groups | 512 |
Priority Queues | 4 |
Packet Buffer Size | 1 Mbits |
LED Interface | |
LED Indicators | PWR1, PWR2, STATE, FAULT, MSTR/HEAD, CPLR/TAIL, SYNC |
Serial Interface | |
Console Port | RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1) |
USB Interface | |
USB Connector | USB Type A (Reserved) |
Input/Output Interface | |
Alarm Contact Channels | 1, Relay output with current carrying capacity of 1 A @ 24 VDC |
Digital Input Channels | 1 |
Digital Inputs | +13 to +30 V for state 1 |
-30 to +3 V for state 0 | |
Max. input current: 8 mA | |
Buttons | Reset button |
DIP Switch Configuration | |
DIP Switches | Turbo Ring, Master, Coupler, Reserve |
Power Parameters | |
Connection | 2 removable 4-contact terminal block(s) |
Pre-installed Power Module | -LV/-LV-T models: PWR-100–LV |
-HV/-HV-T models: PWR-105-HV-I | |
-LVA/-LVA-T models: PWR-101-LV-BP-I | |
-LVB/-LVB-T models: PWR-103-LV-VB-I | |
Note | The EDS-4008 Series supports modular power supplies. The model names and power parameters are determined by the installed power module. |
For example: | |
EDS-4008-T + PWR-100–LV = EDS-4008-LV-T | |
EDS-4008-T + PWR-105-HV-I = EDS-4008-HV-T | |
If you install a different power module, refer to the specifications of the corresponding | |
model. For example, if you replace the power module of the EDS-4008–LV-T | |
with the PWR-105–HV-I, refer to the specifications of the EDS-4008–HV-T. | |
Input Voltage | -LV/-LV-T models: 12/24/48 VDC, Redundant dual inputs |
-HV/-HV-T models: 110/220 VDC/VAC, Single input | |
-LVA/-LVA-T models: 48 VDC, Redundant dual inputs | |
-LVB/-LVB-T models: 12/24/48 VDC, Redundant dual inputs | |
Operating Voltage | -LV/-LV-T models: 9.6 to 60 VDC |
-HV/-HV-T models: 88 to 300 VDC, 85 to 264 VAC | |
-LVA/-LVA-T models: 44 to 57 VDC (> 52 VDC for PoE+ output recommended) | |
-LVB/-LVB-T models: 12 to 57 VDC (> 52 VDC for PoE+ output recommended) | |
Input Current | -LV/-LV-T models: 12-48 VDC, 1.50-0.40 A or 24 VDC, 0.70 A |
-HV/-HV-T models: 110-220 VAC, 50-60 Hz, 0.30-0.20 A or 110-220 VDC, 0.30-0.20 A | |
-LVA/-LVA-T models: 48 VDC, 5.42 A | |
-LVB/-LVB-T models: 12/48 VDC, 7.46/4.27 A or 24 VDC, 7.26 A | |
Power Consumption (Max.) | EDS-4008-LV(-T) models: 7.20 W |
EDS-4008-HV(-T) models: 8.13 W | |
EDS-4008-2MST-LV(-T) models: 8.45 W | |
EDS-4008-2MST-HV(-T) models: 11.13 W | |
EDS-4008-2MSC-LV(-T) models: 8.45 W | |
EDS-4008-2MSC-HV(-T) models: 11.09 W | |
EDS-4008-2SSC-LV(-T) models: 8.98 W | |
EDS-4008-2SSC-HV(-T) models: 11.37 W | |
EDS-4008-2GT-2GS-LV(-T) models: 9.41 W | |
EDS-4008-2GT-2GS-HV(-T) models: 11.17 W | |
EDS-4008-4P-2GT-2GS-LVA(-T) models: | |
Without PoE: 11.22 W | |
With PoE: Max. 240 W for total PD power consumption @ 48 VDC input | |
EDS-4008-4P-2GT-2GS-LVB(-T) models: | |
Without PoE: 15.84 W | |
With PoE: | |
Max. 180 W for total PD power consumption @ 48 VDC input; | |
Max. 150 W for total PD power consumption @ 24 VDC input; | |
Max. 62 W for total PD power consumption @ 12 VDC input | |
Max. PoE Power Output per Port | PoE models: 90 W |
Overload Current Protection | Supported |
Reverse Polarity Protection | Supported |
Physical Characteristics | |
IP Rating | IP40 |
Dimensions | EDS-4008(-T), EDS-4008-2MSC(-T), EDS-4008-2SSC(-T) models: |
55 x 140 x 120 mm (2.2 x 5.51 x 4.72 in) | |
EDS-4008-2MST(-T) models: | |
55 x 140 x 132 mm (2.2 x 5.51 x 5.2 in) | |
EDS-4008-2GT-2GS(-T), EDS-4008-4P-2GT-2GS(-T) models: | |
55 x 140 x 122.5 mm (2.2 x 5.51 x 4.82 in) | |
Weight | EDS-4008(-T) models: 857 g (1.89 lb) |
EDS-4008-2MSC(-T) models: 886 g (1.95 lb) | |
EDS-4008-2MST(-T) models: 810 g (1.79 lb) | |
EDS-4008-2SSC(-T) models: 882 g (1.94 lb) | |
EDS-4008-2GT-2GS(-T) models: 795 g (1.75 lb) | |
EDS-4008-4P-2GT-2GS(-T) models: 840 g (1.85 lb) | |
Installation | DIN-rail mounting, Wall mounting (with optional kit) |
Housing | Metal |
Environmental Limits | |
Operating Temperature | Standard Models: -10 to 60°C (14 to 140°F) |
Wide Temp. Models: -40 to 75°C (-40 to 167°F) | |
Storage Temperature (package included) | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Standards and Certifications | |
Industrial Cybersecurity | IEC 62443-4-1 |
IEC 62443-4-2 | |
Safety | UL 61010-2-201, EN 62368-1 (LVD) |
EMC | EN 55022/24, EN 61000-6-2/-6-4 |
EMI | CISPR 32, FCC Part 15B Class A |
EMS | IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV |
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m | |
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV | |
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV | |
IEC 61000-4-6 CS: 10 V | |
IEC 61000-4-8 PFMF | |
Vibration | IEC 60068-2-6 |
Shock | IEC 60068-2-27 |
Freefall | IEC 60068-2-32 |
Railway | EN 50121-4 |
Traffic Control | NEMA TS2 |
MTBF | |
Time | EDS-4008-LV/-LV-T models: 1,121,399 hrs |
EDS-4008-HV/-HV-T models: 513,575 hrs | |
EDS-4008-2MSC-LV/-LV-T models: 1,014,299 hrs | |
EDS-4008-2MSC-HV/-HV-T models: 492,582 hrs | |
EDS-4008-2MST-LV/-LV-T models: 1,015,718 hrs | |
EDS-4008-2MST-HV/-HV-T models: 492,582 hrs | |
EDS-4008-2SSC-LV/-LV-T models: 1,015,718 hrs | |
EDS-4008-2SSC-HV/-HV-T models: 492,582 hrs | |
EDS-4008-2GT-2GS-LV/-LV-T models: 1,074,099 hrs | |
EDS-4008-2GT-2GS-HV/-HV-T models: 505,936 hrs | |
EDS-4008-4P-2GT-2GS-LVA/-LVA-T models: 923,670 hrs | |
EDS-4008-4P-2GT-2GS-LVB/-LVB-T models: 870,865 hrs hrs | |
Standards | Telcordia SR332 |
Model No. | Description | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|